The global shift towards sustainable energy is imperative to success in reducing CO2 emissions to combat climate change. Energy storage systems play a crucial role in this transition and help save money on energy bills, too. xStorage Hybrid is designed to capture surplus renewable energy, store it efficiently, and release it when demand for energy is high or production of renewable energy is low.
At Eaton, we understand the importance of staying ahead in the ever-evolving energy landscape. That is why we are proud to offer a unique range of solutions that combine to deliver a complete energy infrastructure in buildings, including PV generation and energy storage.
Have a closer look at the different configurations of xStorage Hybrid energy storage system and its accessories.
Technical specifications
Battery Model |
XSTHSBP-5.1-16S-100A-F (Battery 5.12kWh with BMS & HF) |
Physical |
|
Battery type |
LFP (LiFePO4) |
System Weight |
54KG |
Dimensions in mm (W x H x D) |
540*490*240 |
IP Protection |
IP65 |
Warranty |
5 Years Product Warranty,10 Years Performance |
Electrical |
|
Energy Capacity |
5.12kwh |
Usable Capacity |
4.6kwh |
Depth of Discharge (DoD) |
90% |
Rated Voltage |
51.2V |
Operating Voltage Range |
44.8-56.5V |
Internal Resistance |
<20mΩ |
Cycle Life |
10000cycle |
Operation |
|
Max. Charge/Discharge Current |
50A/80A |
Rated DC power |
4096W |
Max. Charge/Discharge Power |
2825W/4096W |
Operating Temperature Range |
-10 to 50℃ charging -10 to 50℃ discharging |
Humidity |
0~95% (No condensation) |
BMS |
|
Modules connection |
Max.5 |
Capacity |
100-500Ah |
Power Consumption |
<2W |
Communication |
CAN & RS485 |
Monitoring Parameters |
System voltage, current, cell voltage, cell temperature, PCBA temperature measurement |
Certificate |
|
Safety (Cell) |
Pack: IEC/EN 62619;UN38.3 Cell: IEC/EN 62619;UN38.3;UL1973 |
Hybrid Inverter Model |
XTHS1P-3.68K |
XSTHS1P-5K |
XSTHS1P-6K |
PV String Input |
|||
Max. Continuous PV Input Power |
8kW |
8kW |
8kW |
Max. DC Voltage |
580V |
||
Nominal Voltage |
400V |
||
MPPT Voltage Range |
80V-560V |
||
Start Voltage 1 |
150V |
||
Number of MPPT |
2 |
||
Strings Per MPPT |
1 |
||
Max. Input Current Per MPPT |
15A |
||
Max. Short-circuit Current Per MPPT |
18A |
||
AC Output (Grid) |
|||
Nominal AC Output Power |
3680W |
5000W |
6000W |
Max. AC Apparent Power |
7360VA (from grid) |
7360VA (from grid) |
7360VA (from grid) |
Max. AC Output Power |
3680W |
5000W1 |
6000W |
Nominal AC Voltage |
230Vac P/N; 2*120V L1/L2(Norway) |
||
AC Grid Frequency Range |
50 / 60Hz±5Hz |
||
Nominal Output Current |
16A |
22A2 |
25A |
Max. Output Current |
20.48A |
28.16A |
32A |
Power Factor (cos ) |
0.8leading-0.8lagging* |
||
THDi |
<3% |
||
Battery Input |
|||
Battery Type |
LFP (LiFePO4) |
||
Nominal Battery Voltage |
51.2V |
51.2V |
51.2V |
Charging Voltage Range |
40-60V |
||
Max. Charging Current |
50A |
100A |
100A |
Max. Discharging Current |
80A |
100A |
100A |
Battery Capacity |
100/200/300/400/500Ah |
||
Charging Rate for Li-ion Battery |
discharge rate is 0.8C, charge rate is 0,5C |
||
AC Output (Backup) |
|||
Nominal AC Output Power |
3680W |
5000W |
6000W |
Max. AC Output Power |
4000VA |
5000VA |
5000VA |
Peak Output Apparent Power |
6900VA 10sec |
6900VA 10sec |
6900VA 10sec |
Max. Output Current |
16A |
20A |
20A |
Nominal Output Voltage |
230V |
||
Nominal Output Frequency |
50/60Hz |
||
Output THDv (@Linear Load) |
<3% (Linear Load) |
||
Efficiency |
|||
Max. PV Efficiency |
97.60% |
||
Euro. PV Efficiency |
97.00% |
||
Protection |
|||
DC Switch |
Bipolar DC Switch (125A/Pole) |
||
Anti-islanding Protection |
Yes |
||
Output Over Current Protection |
Yes |
||
DC Reverse Polarity Protection |
Yes |
||
String Fault Detection |
Yes |
||
AC/DC Surge Protection |
AC Type III; DC Type II |
||
Insulation Detection |
Yes |
||
AC Short Circuit Protection |
Yes |
General Specifications |
|
Dimensions W x H x D |
540*590*240mm |
Weight |
32kg |
Operating Temperature Range |
-25 ~ +60℃ (derating from +45℃) |
Noise (dB) |
<35dB |
System Consumption |
Standby By PV 8.6W -Standby during the night 11W |
Cooling Type |
Natural Convection |
Max. Operation Altitude |
2000m |
Operation Humidity |
0~95% (No Condensation) |
IP Class |
IP65 |
Topology |
Battery Isolation |
Communication |
RS485/CAN2.0/WIFI/4G |
Display |
LCD/APP |
Certification |
|
Certificate |
CE |
Environment |
RoHS, REACH |
Grid Code Compliance |
VDE0126-1; AS 4777.2; NRS 097; VDE-AR-N-4105; CEI0-21; G98; G99; C10/C11 |
Standard |
IEC/EN 62109-1&2; IEC/EN61000-6-1; IEC/EN61000-6-2; EN61000-6-3; IEC/EN61000-6- 4;IEC/EN61000-3-11; EN61000-3-12;IEC60529;IEC 60068; IEC61683; IEC62116; IEC61727; EN50549-1 |
Battery Model |
XSTHSBP-5.1-16S-100A-F (Battery 5.12kWh with BMS & HF) |
Physical |
|
Battery type |
LFP (LiFePO4) |
System Weight |
54KG |
Dimension (W x H x D) |
540*490*240 |
IP Protection |
IP65 |
Warranty |
5 Years Product Warranty, 10 Years Performance |
Electrical |
|
Energy Capacity |
5.12kwh |
Usable Capacity |
4.6kwh |
Depth of Discharge (DoD) |
90% |
Rated Voltage |
51.2V |
Operating Voltage Range |
44.8-56.5V |
Internal Resistance |
<20mΩ |
Cycle Life |
10000cycle |
Operation |
|
Max. Charge/Discharge Current |
50A/100A |
Rated DC power |
4096W |
Max. Charge/Discharge Power |
2825W/4096W |
Operating Temperature Range |
-10 to 50℃ charging -10 to 50℃ discharging |
Humidity |
0~95% (No condensation) |
BMS |
|
Module connection in parallel |
Max. 8 |
Capacity |
200-800Ah |
Power Consumption |
<2W |
Communication |
CAN & RS485 |
Monitoring Parameters |
System voltage, current, cell voltage, cell temperature, PCBA temperature measurement |
Certificate |
|
Safety (Cell) |
Pack: IEC/EN 62619;UN38.3 Cell: IEC/EN 62619;UN38.3;UL1973 |
Hybrid Inverter Model |
XSTHS3P-8K |
XSTHS3P-10K |
XSTHS3P-12K |
PV String Input |
|||
Max. Continuous PV Input Power |
16kW |
20kW |
20kW |
Max. DC Voltage |
1100V |
||
Nominal Voltage |
720V |
||
MPPT Voltage Range |
140V-1000V |
||
MPPT Voltage Range (Full Load) |
380V-850V |
420V-850V |
480V-850V |
Start Voltage 1 |
200V |
||
Number of MPPT |
2 |
||
Strings Per MPPT |
1 |
||
Max. Input Current Per MPPT |
15A |
||
Max. Short-circuit Current Per MPPT |
20A |
||
AC Output (Grid) |
|||
Nominal AC Output Power |
8kW |
10kW |
12kW |
Max. AC Apparent Power |
8.8kVA |
11kVA |
13.2kVA |
Nominal AC Voltage |
400Vac (3P+N+PE); 3*230Vac (between L1/N, L2/N, L3/N) |
||
AC Grid Frequency Range |
50 / 60Hz±5Hz |
||
Nominal Output Current |
11.6A |
14.5A |
17.4A |
Max. Output Current |
12.8A |
16A |
19.2A |
Power Factor (cosφ) |
0.8leading-0.8lagging* |
||
THDi |
< 3% |
||
Battery Input |
|||
Battery Type |
LFP (LiFePO4) |
||
Nominal Battery Voltage |
51.2V |
||
Charging Voltage Range |
44-58V |
||
Max. Charging Current |
160A |
160A |
160A |
Max. Discharging Current |
160A |
200A |
200A |
Battery Capacity |
200/400/600/800Ah |
||
Charging Rate for Li-ion Battery |
discharge rate is 0.8C, charge rate is 0,5C |
||
AC Output (Backup) |
|||
Nominal AC Output Power |
7.36kW |
9.2kW |
9.2kW |
Max. AC Output Power |
8kVA |
10kVA |
10kVA |
Nominal Output Current |
10.7A |
13.3A |
13.3A |
Max. Output Current |
11.6A |
14.5A |
14.5A |
Nominal Output Voltage |
400Vac (3P+N+PE); 3*230Vac (between L1/N, L2/N, L3/N) |
||
Nominal Output Frequency |
50/60Hz |
||
Output THDv (@Linear Load) |
< 2% (Linear Load) |
||
Efficiency |
|||
Max. PV Efficiency |
97.60% |
||
Euro. PV Efficiency |
97.00% |
||
Protection |
|||
Anti-islanding Protection |
Yes |
||
Output Over Current Protection |
Yes |
||
DC Reverse Polarity Protection |
Yes |
||
String Fault Detection |
Yes |
||
AC/DC Surge Protection |
AC Type III; DC Type II |
||
Insulation Detection |
Yes |
||
AC Short Circuit Protection |
Yes |
General Specifications |
|
Dimensions W x H x D |
540*980*240mm |
Weight |
42 kg |
Operating Temperature Range |
-25 ~ +60 (derating +45 ) |
Cooling Type |
Natural Convection |
Noise (dB) |
<45dB |
System Consumption |
Standby by PV 20W - Standby during the night 35W |
Max. Operation Altitude |
2000m |
Operation Humidity |
0~95% (No Condensation) |
IP Class |
IP65 |
Topology |
Battery Isolation |
Communication |
RS485/CAN2.0/WIFI/4G |
Display |
LCD / APP |
Certification |
|
Certificate |
CE |
Environment |
RoHS, REACH |
Grid Code Compliance |
List In Progress |
Standard |
IEC/EN 62109-1&2; IEC/EN61000-6-1; IEC/EN61000-6-2; EN61000-6-3; IEC/EN61000-6-4;IEC/EN61000-3-11; EN61000-3-12;IEC60529;IEC 60068; IEC61683; IEC62116; IEC61727; EN50549-1 |
Configuration |
Description |
Dimensions (mm) Width x Heigh x Depth |
Weight |
Width Space of reservation to install, 600mm on both sides. (Space inside walls) |
XSTHS3P080BP10V1 |
XSTS 3P 8kW 10kWh V1 |
540 x 2210 x 270 |
107 |
1740 |
XSTHS3P080BP20V1 |
XSTS 3P 8kW 20kWh V1 |
1380 x 2210 x 270 |
229 |
2580 |
XSTHS3P080BP30V1 |
XSTS 3P 8kW 30kWh V1 |
2220 x 2210 x 270 |
350 |
3420 |
XSTHS3P080BP40V1 |
XSTS 3P 8kW 40kWh V1 |
2220 x 2210 x 270 |
645 |
3420 |
XSTHS3P100BP10V1 |
XSTS 3P 10kW 10kWh V1 |
540 x 2210 x 270 |
107 |
1740 |
XSTHS3P100BP20V1 |
XSTS 3P 10kW 20kWh V1 |
1380 x 2210 x 270 |
229 |
2580 |
XSTHS3P100BP30V1 |
XSTS 3P 10kW 30kWh V1 |
2220 x 2210 x 270 |
350 |
3420 |
XSTHS3P100BP40V1 |
XSTS 3P 10kW 40kWh V1 |
2220 x 2210 x 270 |
645 |
3420 |
XSTHS3P120BP10V1 |
XSTS 3P 12kW 10kWh V1 |
540 x 2210 x 270 |
107 |
1740 |
XSTHS3P120BP20V1 |
XSTS 3P 12kW 20kWh V1 |
1380 x 2210 x 270 |
229 |
2580 |
XSTHS3P120BP30V1 |
XSTS 3P 12kW 30kWh V1 |
2220 x 2210 x 270 |
350 |
3420 |
XSTHS3P120BP40V1 |
XSTS 3P 12kW 40kWh V1 |
2220 x 2210 x 270 |
645 |
3420 |
Your search "" did not match any documents or products.