The VS6 electronic sensor is used to monitor differential pressure in hydraulic system continuously with 4-20mA signal as well as 2 PNP switch signals.
Sua pesquisa "" não correspondeu com nenhum documento ou produto.
max. operating pressure: | 6,000 psi (stainless steel) 3,200 psi (aluminium) |
max. pressure difference: | 2,320 psi |
operating temperature: | -4°F…176°F |
temperature range of fluid: | -13°F…212°F (NBR) 14°F…212°F (FPM) other temperature ranges on request |
cold start suppression: | < 77°F ± 37.4°F |
power voltage: | +24VDC ±10% |
output signal: | Pin 2, analogue signal:
|
error of measurement: | ± 5% v. Δpnominal by 77°F |
protection: | IP67 |