Maximum reliability for 24 VDC ciuits in your machinery

Higher machine availability with electronic overload protection

Correct protection of control circuits is essential for high availability of machines and systems. Avoiding an automatic switch-off of the switching power supply in the event of an overload or short circuit is one of the essential criteria. Correct protection of control circuits is essential for high availability of machines and systems. Avoiding an automatic switch-off of the switching power supply in the event of an overload or short circuit is one of the essential criteria.   
eaton-roboter_1500_1000

The today in the power of control current circle using switch networked to the output current and are with self-protection against over stream equipment. If the nominal value is exceeded, the switching power supply regulates the output voltage and the connected machine part stops. To prevent this, thermal magnetic miniature circuit breakers are generally used. However, you need very high switch-off currents - if these are not reached, the circuit breaker does not respond, and the switching power supply regulates. In addition, the tripping characteristics of the thermo-specific circuit breakers considerably limit the possible cable lengths. Because the impedance of a line that is too long would reduce the overcurrent to such an extent that the circuit breaker no longer detects the fault. Subsequently, the fuse protection must not react to high system-related inrush currents - it must accordingly have intelligent overcurrent detection.

The whitepaper provides information on the various aspects that must be considered when planning the protection of 24V DC control circuits. It shows how electronic circuit breakers can increase the availability of machines and systems and make the design of the protection of control circuits more efficient.

Protection for 24VDC in special purpose machines for Eaton production sites

System errors do happen. No operator is 100% immune to this type of malfunction. But the big question is: What happens next? Does the downtime affect the entire system, or is it limited to the faulty part? Are hours and hours of troubleshooting required to identify the fault, or can it be corrected within a short period of time? Read how 'Eaton solved this chellange in its own production line.

PXS24 – electronic protection module

Reliable protection for 24 VDC circuits with integrated connectivity

eaton-solution-map-circuit-protection PT012015

Eaton's circuit protection architecture

The PXS24  is implemented into eatons cuircuit protection architecture for the different circuits of a engergy distribution in a factory and a machine. Control circuits are crusial for any machine. Therfore the protetion of 24 VDC circuit is of high importance.

Protections of control circuits with PXS24

PXS24 Protection Module
Selective overload protection in 24VDC Circuits
Digital residual current circuit breaker FRC
Digital residual current circuit breaker
Digital residual current circuit breaker , SmartWire-DT
Digital residual current circuit breaker with SmartWire-DT connection
single and three phase power supplies
PSG single and three-phase power supplies