600VA 300W 120V Standby UPS - 4 NEMA 5-15R Outlets (Surge + Battery Backup), 5-15P Plug, Desktop
| Product Name | 
                                                Eaton Tripp Lite series UPS
                                             | 
| Catalog Number | 
                                                BC600R
                                             | 
| UPC | 
                                                037332282071
                                             | 
| Product Length/Depth | 
                                                7.09 in
                                             | 
| Product Height | 
                                                2.283 in
                                             | 
| Product Width | 
                                                10.04 in
                                             | 
| Product Weight | 
                                                4.41 lb
                                             | 
| Compliances | 
                                                ENERGY STAR certified  FCC Class B RoHS | 
| Certifications | 
                                                CSA Std. C22.2  NOM UL 1778 | 
| Global Catalog | 
                                                BC600R
                                             | 
| Topology | 
                                                Standby
                                             | 
| Form factor | 
                                                Desktop/Surface mount/Wall-mount
                                             | 
| Package contents | 
 | 
| Input cord length | 
                                                5 ft
                                             | 
| Input nominal voltage | 
                                                120 VAC
                                             | 
| Nominal frequency | 
                                                50/60 Hz
                                             | 
| Input frequency range | 
                                                50/60 Hz
                                             | 
| Receptacle | 
                                                5-15R
                                             | 
| Output nominal voltage | 
                                                120V
                                             | 
| Electric current - max | 
 | 
| Battery type | 
                                                Valve Regulated Lead Acid (VRLA)
                                             | 
| Runtime at half load | 
                                                5 min
                                             | 
| Noise level | 
                                                Less than 40dB front side 1m
                                             | 
| Relative humidity | 
                                                0-95% non-condensing
                                             | 
| Input Plug Type | 
                                                NEMA 5-15P
                                             | 
| Output Receptacles | 
                                                5-15R
                                             | 
| Product Highlights | 
                                                Recommended for locations where temperatures range within 32° and 122° F  Automatically restarts when power is restored, saving you a costly site visit Low-maintenance UPS sets up in minutes to start backing up your equipment Protects up to 4 devices against outages, brownouts, overvoltages, surges and line noise Keeps power running during brief outages to allow time for safe system shutdown Recommended for locations where temperatures range within 32° and 122° F | 
| Nominal Output Voltage | 
                                                120V
                                             | 
| Network Management Cards Details | 
                                                Network management not supported
                                             | 
| Input voltage range | 
                                                120VAC
                                             | 
| Output power factor | 
                                                0.5
                                             | 
| Phase (input) | 
                                                Single-phase
                                             | 
| Runtime at full load | 
                                                1.2 min. (300W)
                                             | 
| Communication interface | 
                                                None
                                             | 
| Battery Access | 
                                                Base-mounted battery access panel
                                             | 
| Battery Voltage (VDC) | 
                                                12
                                             | 
| Dc Voltage | 
                                                12
                                             | 
| Operating Temperature Range | 
                                                32° to 122°F (0° to 50°C)
                                             | 
| Input Circuit Breakers | 
                                                (1) 7A
                                             | 
| High Voltage Transfer to Battery Power | 
                                                145V
                                             | 
| Low Voltage Transfer to Battery Power | 
                                                95V
                                             | 
| Application | 
 | 
| Switch configuration | 
                                                Includes 1 on/off/alarm mute/alarm enable momentary push button. Press for 1 second for  ON, Press and hold 2 seconds for OFF. Press and hold 10 seconds to enable alarm/ disable alarm (Default)
                                             | 
| AC suppression joule rating | 
                                                190
                                             | 
| Housing material | 
                                                ABS
                                             | 
| Output AC waveform (AC mode) | 
                                                Sine wave
                                             | 
| Output AC waveform (battery mode) | 
                                                PWM sine wave
                                             | 
| Output Capacity (kVA) | 
                                                0.6
                                             | 
| Output Capacity (kW) | 
                                                0.3
                                             | 
| Output Capacity (VA) | 
                                                600
                                             | 
| Operating Elevation | 
                                                0-2000
                                             | 
| AC Suppression Response Time | 
                                                Instantaneous
                                             | 
| Alarm Interface | 
                                                Press and hold On/Off/Test button for 1 second
                                             | 
| Audible Alarms | 
                                                Yes
                                             | 
| Battery Start Capability | 
                                                Cold Start operation supported
                                             | 
| Cooling Method | 
                                                Convection
                                             | 
| Battery Replacement Description | 
                                                RBC36H
                                             | 
| LED Indicators | 
                                                GREEN - ON SOLID GREEN when the line input voltage is normal. FLASH GREEN when the UPS is supplying battery power to the loads. RED - Flashes when the battery needs to be recharged and tested.
                                             | 
| Frequency Rating Details | 
                                                50 or 60Hz +/- 5Hz (Auto-sensing)
                                             | 
| Output Voltage Regulation(Battery Mode) | 
                                                -0.1
                                             | 
| Rechargeable Battery | 
                                                Less than 8 hours from 10% to 90%
                                             | 
| Recommended Electrical Service | 
                                                15A 120V
                                             | 
| Storage Temperature | 
                                                5° to 122°F (-15° to 50°C)
                                             | 
| Nominal Voltage Details | 
                                                120V
                                             | 
| Maximum Input Amps | 
                                                5
                                             | 
| UPS Input Cord Length (m) | 
                                                1.5
                                             | 
| Power Mode Transfer Time | 
                                                4 - 6 milliseconds (typical) / 10 milliseconds (max)
                                             | 
| EMI AC Noise Suppression | 
                                                EMI / RFI AC Noise Suppression
                                             | 
| UPS Input Connection Type | 
                                                5-15P
                                             | 
| Green Energy-Saving Features | 
                                                Greater than 95% efficiency - GREEN UPS  High efficiency economy mode operation | 
| Input Cord Color | 
                                                Black
                                             | 
| High Availability UPS Features | 
                                                Surge/noise protection
                                             |