1.5kW Single-Phase Local Metered PDU + ISOBAR Surge Suppression, 3840 Joules, 100-127V Outlets (14 5-15R), 5-15P, 15 ft. (4.57 m) Cord, 1U Rack-Mount
Product Name |
Eaton Tripp Lite series metered outlet PDU
|
Catalog Number |
PDUMH15-ISO
|
UPC |
037332183248
|
Product Length/Depth |
4.5 in
|
Product Height |
20 in
|
Product Width |
2 in
|
Product Weight |
4.6 lb
|
Compliances |
RoHS
TAA Compliant |
Certifications |
NOM
UL 1449 RETIE |
Form factor |
1U
|
Package contents |
|
Operating Temperature |
32° to 104°F (0° to 40°C)
|
Mounting direction |
Horizontal
|
Material |
Metal
|
Input connection |
NEMA 5-15P
|
Cord length |
15 ft
|
Amperage Rating |
12A
|
Electric current - max |
12
|
Phase |
Single-phase
|
Frequency rating |
50/60 Hz
|
Number of Outputs 5-15R |
14
|
Features |
Flex Center
|
Front Panel LCD Display |
Two digit current meter reports PDU output load in amps
|
Output Receptacles |
5-15R
|
AC suppression joule rating |
3840
|
AC suppression response time |
NM = 0 ns. CM = <1 ns
|
EMI/RFI filtering |
40-80 dB
|
AC suppression surge current rating |
60,000 amps
|
Clamping voltage |
140
|
Grounding options |
Rear grounding lug
|
LED indicators |
Set of 3 diagnostic LEDs continuously report status for LINE OK (green), suppressor or wiring FAULT (red) and PROTECTION PRESENT (green)
|
Minimum required rack depth |
7.5 in
|
Overload protection |
15A Breaker
|
Protection type |
Includes full normal mode (H-N) and common mode (N-G / H-G) line surge suppression
|
Recommended electrical service |
Single-phase 15A 100-127V service
|
Receptacles |
5-15R
|
Immunity |
Conforms to IEEE 587 / ANSI C62.41
|
Input Cord Length |
15 ft
|
Switch configuration |
No power switch
|
Product Features |
Automatic Shut-Off
|
Amperage Rating Details |
Agency de-rated to 12A continuous
|
Operating elevation |
0-10000 ft. (0-3000 m)
|
Operating temperature range |
32° to 104°F (0° to 40°C)
|
Output nominal voltage |
100-127V
|
Relative humidity |
5% to 95% non-condensing
|
Form Factors Supported |
1U rackmount, 0U vertical rackmount, wall-mount, and under-counter installation
|
Output Capacity Details |
1.52kW (127V), 1.44kW (120V), 1.2kW (100V) / 12A total capacity; 12A max per outlet
|
Output Capacity (kW) |
1.52 kW
|
Storage temperature |
-22° to 122°F (-30° to 50°C)
|
Product Highlights |
Local Metered single phase 12A 100-127V PDU with Isobar Surge Suppression
1U Horizontal rackmount, Digital current meter 3840 Joule suppression rating, Diagnostic LEDs 14 NEMA 5-15R outlets (2 front / 12 rear) NEMA 5-15P input; 15-ft. / 4.5m line cord Reversible housing; 4.5in /11.4cm depth |
PDU Plug Type |
5-15P
|
PDU Type |
Local metered
|
PDU Input Voltage |
100
|
PDU Form Factor |
Horizontal (1U)
|