1440VA 1000W 120V Line-Interactive Cloud-Connected UPS with Remote Monitoring - 10 NEMA 5-15R Outlets (5 Surge + 5 Surge and Battery Backup), Extended Run, LCD, 5-15P Plug, Tower
| Product Name | 
                                                Eaton Tripp Lite series standby UPS
                                             | 
| Catalog Number | 
                                                SMART1500LCDTXC
                                             | 
| UPC | 
                                                037332281340
                                             | 
| Product Length/Depth | 
                                                14.567 in
                                             | 
| Product Height | 
                                                7.874 in
                                             | 
| Product Width | 
                                                5.906 in
                                             | 
| Product Weight | 
                                                28.66 lb
                                             | 
| Compliances | 
                                                ENERGY STAR certified  FCC Class B RoHS | 
| Certifications | 
                                                CSA Std. C22.2  CSA certified ICES NOM UL 1778 RETIE | 
| Global Catalog | 
                                                SMART1500LCDTXC
                                             | 
| Battery Access | 
                                                Battery access door
                                             | 
| Battery Replacement Description | 
                                                RBC51 (Quantity 2)
                                             | 
| LED Indicators | 
                                                Green Solid: Running on AC power, Battery Fully Charged. Green Flashing: Running on AC power, Battery charging. Red: Fault
                                             | 
| Rechargeable Battery | 
                                                8 hours (10% to 90%)
                                             | 
| Output nominal voltage | 
                                                110 / 120V
                                             | 
| Nominal Output Voltage | 
                                                110V  115V 120V | 
| Electric current - max | 
 | 
| Input cord length | 
                                                5 ft
                                             | 
| Input nominal voltage | 
                                                120 VAC
                                             | 
| Nominal frequency | 
                                                50/60 Hz
                                             | 
| Input frequency range | 
                                                50/60 Hz
                                             | 
| Input Circuit Breakers | 
                                                15A
                                             | 
| Recommended Electrical Service | 
                                                15A 120V
                                             | 
| Relative humidity | 
                                                0-90% non-condensing
                                             | 
| Operating Temperature Range | 
                                                32° to 104°F (0° to 40°C)
                                             | 
| Topology | 
                                                Line-interactive
                                             | 
| Form factor | 
                                                Tower
                                             | 
| Package contents | 
 | 
| Application | 
 | 
| Audible Alarms | 
                                                UPS remains silent in battery backup mode; Alarm sounds only to report low-battery, fault, overload and replace-battery conditions
                                             | 
| Alarm Interface | 
                                                Power-fail alarm can be silenced via front LCD display or via Remote Monitoring Application
                                             | 
| Nominal Voltage Details | 
                                                120v nominal output in battery mode
                                             | 
| Runtime at half load | 
                                                10 min
                                             | 
| Runtime at full load | 
                                                2 min. (1000W)
                                             |