Tripp Lite series SmartOnline 5000VA 4500W 120/208V Online Double-Conversion UPS - L6-30P, 18x 5-20R, 2 L6-20R, 1 L6-30R Outlets, Network Card, Extended Run, 6U Rack/Tower
Product Name |
Eaton Tripp Lite series SmartOnline UPS
|
Catalog Number |
SU5000RTF
|
UPC |
037332286352
|
Product Length/Depth |
28.4 in
|
Product Height |
10.2 in
|
Product Width |
17.3 in
|
Product Weight |
201 lb
|
Compliances |
CE Marked
FCC Compliant RoHS ENERGY STAR certified FCC Class A REACH |
Certifications |
IEC/EN 62040-2
NOM CSA 22.2 cTUVus UL 1778 |
Global Catalog |
SU5000RTF
|
Battery replacement |
EBP-1803
|
Battery type |
Valve Regulated Lead Acid (VRLA)
|
Extended battery capability |
Add up to 4 extended battery modules (EBM). Part number BP180RT
|
Runtime at full load |
3 min. (4500W)
|
Runtime at half load |
11 min
|
High Voltage Transfer to Battery Power |
276V
|
Low Voltage Transfer to Battery Power |
176V
|
Output Voltage Regulation (Line Mode) |
+/- 1%
|
Output Voltage Regulation(Battery Mode) |
+/- 1%
|
Receptacle |
(18) 5-20R; (1) Hardwire (200-240V); (2) L6-20R; (1) L6-30R
|
Topology |
Online/Double-conversion
|
Wattage |
4500 W
|
Output waveform |
True sine wave
|
Output power factor |
0.9
|
Voltage |
120/208V
|
Output nominal voltage |
120/240V default (200/208/220/230/240V)
|
Nominal Output Voltage |
120V
200V 208V 220V 230V 240V |
Output frequency |
50/60 Hz
|
Electric current - max |
23.3A
|
Current Crest Ratio |
3:1
|
Input connection |
Hardwire; L6-30P
|
Input cord length |
10 ft
|
Input nominal voltage |
208V default (200/208/220/230/240V)
|
Input Nominal Voltage |
200 VAC
208 VAC 220 VAC 230 VAC 240 VAC Factory configured to 208V |
Input voltage range |
200-240V
|
Input power factor |
>0.99 typical
|
Input Circuit Breakers |
Recommended 30A upstream
|
Ethernet interface |
Yes
|
Includes network card |
Yes
|
Software compatibility |
PowerAlert
|
Altitude |
<1000m for nominal power, 10% power degrading every 1000m (up to 3000m)
|
Noise level |
<45 dB at 1 meter
|
Relative humidity |
0-95% non-condensing
|
Temperature range |
0° to 40°C (32° to 104°F)
|
Operating Temperature Range |
32° to 104°F (0° to 40°C)
|
Form factor |
Rack/tower
|
Rack size |
6U
|
Rack mounting kit |
Yes
|
Efficiency at max. load |
93%
|
Switch configuration |
RPO / ROO
|
Phase (input) |
Single-phase
|
Surge protection |
Yes
|
Internal bypass |
Yes
|
Package contents |
|
Total Harmonic Distortion |
< 2% THDV on linear load; < 5% THDV on non-linear load
|
EMI AC Noise Suppression |
EMI / RFI AC Noise Suppression
|
Green Energy-Saving Features |
High efficiency economy mode operation
|
Standard factory warranty |
|